Zoo heev 0u Vertical Intelligent Khib PDU, 3 Theem, Metered-los-Qhov Chaw Nrog Hloov, 63A, (24) C13 Qhov hluav taws xob
Zoo heev 1st, thiab Client Supreme yog peb cov lus qhia kom xa cov neeg muab kev pabcuam zoo tshaj plaws rau peb lub zeem muag.Tam sim no, peb tau nrhiav peb qhov zoo tshaj plaws los ua ib tus neeg xa khoom zoo tshaj plaws hauv peb cov kev qhuab qhia kom tau raws li cov neeg yuav khoom xav tau rau qhov zoo tshaj plaws 0u Vertical Intelligent Rack PDU, 3 Phase, Metered-by-Outlet nrog Switching, 63A, (24) C13 Qhov hluav taws xob, Rau cov khoom siv roj vuam zoo & txiav cov khoom xa tuaj raws sijhawm thiab ntawm tus nqi tsim nyog, koj tuaj yeem suav rau lub koom haum lub npe.
Zoo heev 1st, thiab Client Supreme yog peb cov lus qhia kom xa tus neeg muab kev pabcuam zoo tshaj plaws rau peb lub zeem muag.Tam sim no, peb tau nrhiav peb qhov zoo tshaj plaws los ua ib tus neeg xa khoom zoo tshaj plaws hauv peb cov kev qhuab qhia kom tau raws li cov neeg yuav khoom xav tau ntau dua.Tuam Tshoj Intelligent PDU thiab 3 kab lus PDU, Lub tuam txhab lub npe, yog ib txwm hais txog kev ua tau zoo raws li lub tuam txhab lub hauv paus, nrhiav kev txhim kho los ntawm qib siab ntawm kev ntseeg siab, ua raws li ISO kev tswj hwm tus qauv nruj me ntsis, tsim lub tuam txhab saum toj kawg nkaus los ntawm tus ntsuj plig ntawm kev nce qib-kev ua siab ncaj thiab kev cia siab.
Nta
● Modular qauv kom yooj yim customization. Tau tshaj feem ntau ntawm cov qauv kev lag luam nrog CE, GS, UL, NF, EESS thiab lwm yam ntawv pov thawj nrov.
● Tej thaj chaw deb saib xyuas thiab tswj. Muab cov kev hloov tshiab tam sim ntawd txog cov xwm txheej fais fab ntawm email, SMS ntawv, lossis SNMP ntxiab Upgradeable Firmware. Downloadable firmware hloov tshiab los txhim kho cov kev pab cuam uas khiav PDU.
● Digital Display. Muab cov ntaub ntawv yooj yim nyeem txog amperage, voltage, KW, IP chaw nyob, thiab lwm yam ntaub ntawv PDU.
● Network-Qib Plugs thiab Outlets. Kev tsim kho kom ruaj khov ua kom muaj txiaj ntsig zoo ntawm kev faib hluav taws xob rau cov servers, khoom siv, thiab cov khoom siv txuas nrog hauv kev xav tau IT lossis kev lag luam ib puag ncig.
● Durable Hlau Casing. Tiv thaiv cov khoom siv sab hauv thiab tiv thaiv kev puas tsuaj los ntawm kev cuam tshuam lossis kev puas tsuaj nyob rau hauv ib puag ncig nyuaj. Kuj txuas lub neej ntawm cov khoom.
● Peb Lub Xyoo Txwv Warranty. Npog qhov tsis xws ntawm cov ntaub ntawv thiab kev ua haujlwm hauv cov khoom raws li kev siv ib txwm siv thiab cov xwm txheej hauv peb xyoos ntawm hnub yuav khoom.
Muaj nuj nqi
Newsunn ntse PDUs muaj A, B, C, D qauv. A & B hom muaj kev ua haujlwm ntawm kev saib xyuas cov chaw taws teeb thiab kev tswj cov chaw taws teeb: Ib hom tuaj yeem siv tag nrho cov khoom siv hluav taws xob thiab cov ceg hluav taws xob saib xyuas thiab tswj; B hom tsuas tuaj yeem siv tag nrho cov kev soj ntsuam xyuas thiab kev tswj xyuas. C & D hom muaj kev saib xyuas tej thaj chaw deb: C hom tuaj yeem saib xyuas ob qho tib si ntawm tag nrho cov Circuit Court thiab ceg Circuit Court; Hom D tsuas tuaj yeem saib xyuas tag nrho lub voj voog. Cov lus hauv qab no yog qhov yooj yim dua kom pom qhov txawv.
Lub luag haujlwm tseem ceeb | Kev qhia ntawv | Cov Qauv Ua Haujlwm | |||
A | B | C | D | ||
Saib xyuas | Tag nrho cov load tam sim no | ● | ● | ● | ● |
Load tam sim no ntawm txhua qhov hluav taws xob | ● | ● | ● | ||
On/Off lub xeev ntawm txhua qhov hluav taws xob | ● | ● | |||
Tag nrho lub zog (kw) | ● | ● | ● | ● | |
Tag nrho lub zog noj (kw) | ● | ● | ● | ● | |
Ua haujlwm voltage | ● | ● | ● | ● | |
Ntau zaus | ● | ● | ● | ● | |
Kub / Humidity | ● | ● | ● | ● | |
Smog sensor | ● | ● | ● | ● | |
Qhov rooj sensor | ● | ● | ● | ● | |
Dej ntsuas sensor | ● | ● | ● | ● | |
Tswj | On/off ntawm lub zog | ● | ● | ||
On/off ntawm txhua qhov hluav taws xob | ● | ||||
Teem lub sij hawm ncua sij hawm ntawm qhov hluav taws xob 'sequential on/off | ● | ||||
Teem lub sijhawm qhib / tawm ntawm txhua qhov hluav taws xob | ● | ||||
Teem txwv tus nqi rau lub tswb | Limiting ntau yam ntawm tag nrho cov load tam sim no | ● | ● | ● | ● |
Limiting ntau yam ntawm load tam sim no ntawm txhua qhov hluav taws xob | ● | ● | |||
Qhov limiting ntau yam ntawm kev ua haujlwm voltage | ● | ● | ● | ● | |
Qhov limiting ntau yam ntawm qhov kub thiab txias | ● | ● | ● | ● | |
System tsis siv neeg tswb | Tag nrho cov load tam sim no tshaj qhov txwv tus nqi | ● | ● | ● | ● |
Lub load tam sim no ntawm txhua qhov hluav taws xob tshaj qhov txwv tus nqi | ● | ● | ● | ● | |
Kub / av noo tshaj qhov txwv tus nqi | ● | ● | ● | ● | |
Smog | ● | ● | ● | ● | |
Kev kaw dej | ● | ● | ● | ● | |
Qhov rooj qhib | ● | ● | ● | ● |
Technical Parameters
Yam khoom | Parameter | |
Tswv yim | Hom tswv yim | AC 1-theem, 3-theem, 48VDC, 240VDC, 336VDC |
Hom tswv yim | Lub hwj chim qaum, lub qhov (socket), muaj qhov (socket), thiab lwm yam. | |
Input Voltage Range | 100-277VAC / 312VAC-418VAC / 100VDC-240VDC / -43VDC- -56VDC | |
AC zaus | 50/60Hz | |
Tag nrho cov load tam sim no | 63A ntawm qhov siab tshaj plaws | |
Tso zis | Output voltage ntsuas | 220VAC, 250VAC, 380VAC, -48VDC, 240VDC, 336VDC |
Tso zis zaus | 50 / 60Hz | |
Cov qauv tsim tawm | IEC C13, C19, German tus qauv, UK tus qauv, Asmeskas tus qauv, kev lag luam hauv IEC 60309 thiab lwm yam | |
Cov zis ntau | 48 qhov hluav taws xob ntawm qhov siab tshaj plaws |
Kev sib txuas lus muaj nuj nqi
● Cov neeg siv tuaj yeem tshawb xyuas qhov kev teeb tsa kev ua haujlwm thiab kev tswj hwm lub zog ntawm cov chaw taws teeb ntawm WEB, SNMP.
● Cov neeg siv tuaj yeem hloov kho cov firmware sai thiab yooj yim ntawm kev rub tawm network rau kev txhim kho cov khoom lag luam yav tom ntej es tsis txhob
hloov cov khoom uas twb tau teeb tsa hauv thaj teb thaum cov yam ntxwv tshiab tso tawm.
Kev them nyiaj yug Interface thiab raws tu qauv
● HTTP
● SNMP V1 V2
● MODBUS TCP/IP
● MODBUS RTU (RS-485)
● FTP
● IPV4 Kev them nyiaj yug
● Telnet
Accessory
Hom qhov (socket).
Zoo heev 1st, thiab Client Supreme yog peb cov lus qhia kom xa cov neeg muab kev pabcuam zoo tshaj plaws rau peb lub zeem muag.Tam sim no, peb tau nrhiav peb qhov zoo tshaj plaws los ua ib qho ntawm cov neeg xa khoom zoo tshaj plaws hauv peb cov kev qhuab qhia kom tau raws li cov neeg yuav khoom xav tau rau cov khoom zoo tshaj plaws Vertical Intelligent PDU, 3 Theem, Metered-by-Outlet nrog Switching, 63A, (24) C13 Qhov hluav taws xob, Rau cov khoom siv roj vuam zoo & txiav cov khoom siv raws sijhawm thiab ntawm tus nqi tsim nyog, koj tuaj yeem suav rau lub koom haum lub npe.
Zoo heevTuam Tshoj Intelligent PDU thiab 3 kab lus PDU, Lub tuam txhab lub npe, yog ib txwm hais txog kev ua tau zoo raws li lub tuam txhab lub hauv paus, nrhiav kev txhim kho los ntawm qib siab ntawm kev ntseeg siab, ua raws li ISO kev tswj hwm tus qauv nruj me ntsis, tsim lub tuam txhab saum toj kawg nkaus los ntawm tus ntsuj plig ntawm kev nce qib-kev ua siab ncaj thiab kev cia siab.